Traverse
unit for a particular application is selected considering the following
details.
1)
The Force required to traverse the material,
2) Linear speed required,
3) Total mass to be traversed ( Including weight of RollringTraverse Unit and Associated Assemblies),
4) Shaft speed,
5) Moment of inertia at reversal points and frictional force of load
carriers/ separately mounted guide assemblies if any.
Separate
load carrier for mounting the guide assembly is recommended for
applications having any of the following requirements.
a)
Heavy guide assembly
b) Large overhang required for the guide assembly
c) Strong twisting forces / large tension is present in the
material to be traversed.
By using the load carrier forces acting on the traverse unit will be
considerably reduced and smaller model of traverse unit can be used to
traverse heavy loads.
Pre
Selection: A unit needs to be pre selected by estimating
approximately the total force required and / or considering the maximum
shaft sag. The suitability of the unit so preselected needs to be
verified as described below
Calculation
of Side Thrust F Required For an Application:
F
= 0.25 (m x v/t) + Fr + Fz + 0.12 m×g +Fw
The
value of side thrust F so calculated should be less than rated
side thrust of the Rollring traverse unit selected.
F < F RR
F RR: Rated Side Thrust Of The Rollring Traverse Unit
Selected.
If the required side thrust F calculated is higher than that of the
traverse unit pre selected F RR, higher size unit
needs to be selected. Select a higher size traverse unit and verify the
suitability as above . |